71 research outputs found

    A Comparative Study of Three Different Types of Stem Cells for Treatment of Rat Spinal Cord Injury

    Get PDF
    Three different sources of human stem cells-bone marrow-derived mesenchymal stem cells (BM-MSCs), neural progenitors (NPs) derived from immortalized spinal fetal cell line (SPC-01), and induced pluripotent stem cells (iPSCs)-were compared in the treatment of a balloon-induced spinal cord compression lesion in rats. One week after lesioning, the rats received either BM-MSCs (intrathecally) or NPs (SPC-01 cells or iPSC-NPs, both intraspinally), or saline. The rats were assessed for their locomotor skills (BBB, flat beam test, and rotarod). Morphometric analyses of spared white and gray matter, axonal sprouting, and glial scar formation, as well as qPCR and Luminex assay, were conducted to detect endogenous gene expression, while inflammatory cytokine levels were performed to evaluate the host tissue response to stem cell therapy. The highest locomotor recovery was observed in iPSC-NP-grafted animals, which also displayed the highest amount of preserved white and gray matter. Grafted iPSC-NPs and SPC-01 cells significantly increased the number of growth-associated protein 43 (GAP43+) axons, reduced astrogliosis, downregulated Casp3 expression, and increased IL-6 and IL-12 levels. hMSCs transiently decreased levels of inflammatory IL-2 and TNF-alpha. These findings correlate with the short survival of hMSCs, while NPs survived for 2 months and matured slowly into glia- and tissue-specific neuronal precursors. SPC-01 cells differentiated more in astroglial phenotypes with a dense structure of the implant, whereas iPSC-NPs displayed a more neuronal phenotype with a loose structure of the graft. We concluded that the BBB scores of iPSC-NP- and hMSC-injected rats were superior to the SPC-01-treated group. The iPSC-NP treatment of spinal cord injury (SCI) provided the highest recovery of locomotor function due to robust graft survival and its effect on tissue sparing, reduction of glial scarring, and increased axonal sprouting

    Measurement of the Depth of Maximum of Extensive Air Showers above 10^18 eV

    Get PDF
    We describe the measurement of the depth of maximum, Xmax, of the longitudinal development of air showers induced by cosmic rays. Almost four thousand events above 10^18 eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106 +35/-21) g/cm^2/decade below 10^(18.24 +/- 0.05) eV and (24 +/- 3) g/cm^2/decade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm^2. The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.Comment: Accepted for publication by PR

    Operations of and Future Plans for the Pierre Auger Observatory

    Full text link
    Technical reports on operations and features of the Pierre Auger Observatory, including ongoing and planned enhancements and the status of the future northern hemisphere portion of the Observatory. Contributions to the 31st International Cosmic Ray Conference, Lodz, Poland, July 2009.Comment: Contributions to the 31st ICRC, Lodz, Poland, July 200

    Nifedipin ublažava djelovanje kokaina na enzimsku aktivnost u mozgu i jetri te smanjuje njegovo izlučivanje putem mokraće

    Get PDF
    The aim of this study was to see how nifedipine counters the effects of cocaine on hepatic and brain enzymatic activity in rats and whether it affects urinary excretion of cocaine. Male Wistar rats were divided in four groups of six: control, nifedipine group (5 mg kg-1 i.p. a day for five days); cocaine group (15 mg kg-1 i.p. a day for five days), and the nifedipine+cocaine group. Twenty-four hours after the last administration, we measured neuronal nitric oxide synthase (nNOS) activity in the brain and cytochrome P450 quantity, ethylmorphine-N-demethylase, and anilinehydroxylase activity in the liver. Urine samples were collected 24 h after the last cocaine and cocaine+nifedipine administration. Urinary cocaine concentration was determined using the GC/MS method. Cocaine administration increased brain nNOS activity by 55 % (p<0.05) in respect to control, which indicates the development of tolerance and dependence. In the combination group, nifedipine decreased the nNOS activity in respect to the cocaine-only group. In the liver, cocaine significantly decreased and nifedipine significantly increased cytochrome P450, ethylmorphine-N-demethylase, and anilinehydroxylase in respect to control. In combination, nifedipine successfully countered cocaine effects on these enzymes. Urine cocaine excretion in the cocaine+nifedipine group significantly dropped (by 35 %) compared to the cocaine-only group. Our results have confirmed the effects of nifedipine against cocaine tolerance and development of dependence, most likely due to metabolic interactions between them.Cilj je ovoga istraživanja bio utvrditi kako nifedipin ublažava djelovanje kokaina na enzimsku aktivnost u mozgu i jetri Wistar štakora te utječe li na njegovo izlučivanje putem mokraće. Mužjaci su podijeljeni u četiri skupine po šest jedinki: kontrolnu skupinu, nifedipinsku skupinu koja je pet dana intraperitonealno primala nifedipin u dozi od 5 mg kg-1; skupinu koja je pet dana primala kokain u dozi od 15 mg kg-1 na dan te skupinu koja je zajedno primala nifedipin i kokain u odgovarajućim dozama. Dvadeset i četiri sata nakon posljednje doze izmjerena je enzimska aktivnost sintaze dušičnoga oksida (nNOS) u mozgu, razina citokroma P450 te aktivnosti enzima etilmorfi n-N-demetilaze i anilinhidroksilaze u jetri štakora. Uzorci mokraće prikupljeni su 24 sata nakon posljednje doze kokaina odnosno kombinacije nifedipina i kokaina. Koncentracija kokaina u mokraći izmjerena je s pomoću vezanog sustava plinske kromatografi je i spektrometrije masa. Kokain je povećao aktivnost nNOS-a u mozgu za 55 % (p<0,05) u odnosu na kontrolnu skupinu, što upućuje na stvaranje tolerancije i ovisnosti. U kombiniranoj skupini nifedipin je značajno smanjio aktivnost nNOS-a u odnosu na skupinu koja je primila samo kokain. Kokain je značajno snizio, a nifedipin značajno povisio razinu citokroma P450 u jetri te aktivnost etilmorfi n-N-demetilaze i anilinhidroksilaze u odnosu na kontrolnu skupinu. U kombiniranoj skupini nifedipin je uspješno ublažio djelovanje kokaina na aktivnost spomenutih enzima. Izlučivanje kokaina putem mokraće u kombiniranoj skupini bilo je značajno manje (35 %) nego u skupini koja je primala samo kokain. Ovi rezultati potvrđuju da nifedipin štiti od djelovanja kokaina i stvaranja ovisnosti, najvjerojatnije zbog interakcija u metabolizmu dvaju spojeva

    The exposure of the hybrid detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The "hybrid" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    Anisotropy and chemical composition of ultra-high energy cosmic rays using arrival directions measured by the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Collaboration has reported evidence for anisotropy in the distribution of arrival directions of the cosmic rays with energies E>Eth=5.5×1019E>E_{th}=5.5\times 10^{19} eV. These show a correlation with the distribution of nearby extragalactic objects, including an apparent excess around the direction of Centaurus A. If the particles responsible for these excesses at E>EthE>E_{th} are heavy nuclei with charge ZZ, the proton component of the sources should lead to excesses in the same regions at energies E/ZE/Z. We here report the lack of anisotropies in these directions at energies above Eth/ZE_{th}/Z (for illustrative values of Z=6, 13, 26Z=6,\ 13,\ 26). If the anisotropies above EthE_{th} are due to nuclei with charge ZZ, and under reasonable assumptions about the acceleration process, these observations imply stringent constraints on the allowed proton fraction at the lower energies

    Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter

    Get PDF
    Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{6×10196\times 10^{19}eV}. The anisotropy was measured by the fraction of arrival directions that are less than 3.13.1^\circ from the position of an active galactic nucleus within 75 Mpc (using the V\'eron-Cetty and V\'eron 12th12^{\rm th} catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (386+7)(38^{+7}_{-6})%, compared with 2121% expected for isotropic cosmic rays. This is down from the early estimate of (6913+11)(69^{+11}_{-13})%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section
    corecore